File conventions-------------------------------------

Rule #1: Data exists in one and only one location at a given time.
Exception: *CUST.ZIP contain data files from other *.ZIP files.

*PTX1.ZIP		Prototype data, revision X1, X2,...X9.
*DSGN.ZIP		Design files, schematic, layout, boms, etc.
*PRNT.ZIP		Checkprints in PDF format, older versions in postscript
*CAM1.ZIP		Manufacturing data, 1-up
*CAM2.ZIP		Manufacturing data, panelized
*CUST.ZIP		Customer data: checkprints, mfg data, design files

*.PCB/JOB		PCB layout design file
*.SCH/DSN		PCB schematic design file

*.DRL			N/C drill
*.PHO			Gerber data
SMD*.PHO		Gerber data for solderpaste stencil
*CENT.ASC/.TXT	Assembly centroid (pick&place) data

*FAB*.PDF/.TXT	Fabrication documentation
*ASY*.PDF/.TXT	Assembly documentation

*ASY.BOM		Bill of materials for assembly
*TEL.BOM		Bill of materials for quickstart

Documentation packages---------------------------------------

For Fabrication: assemble a *FAB.ZIP having the following files.
From *CAM2.ZIP:	all n/c drill and gerber data except stencil gerber data. 			all fabrication documentation.

For Assembly: assemble a *ASY.ZIP having the following files.
From *DSGN.ZIP:	bill of for assembly (or get from PC manager)
From *CAM1.ZIP:	centroid data
			gerber data of silkscreen and solderpaste stencil layers

For Solderpaste Stencil: assemble a *SCTL.ZIP having the following files.
From *CAM2.ZIP: gerber data for solderpaste stencil

End------------------------------------------------------------------------